In Cape Town, for example, you may not store more than 100 kg of flammable gas or 200 litres of flammable liquid in the main danger groups without a flammable substance certificate. Regulations change. Confirm the current requirement with the authority named in each section before you commit money. CISH supplies, installs and commissions complete production lines and provides the layout and equipment data your fire engineer and municipality need.
Three things people mean by "fire compliance"
| What it is | Who issues or checks it | When you need it |
|---|---|---|
| Building fire approval | Municipal building control and fire department, on plans prepared to the National Building Regulations | New buildings, alterations and changes of use |
| Flammable substance certificate | Municipal fire department (the controlling authority) | Storing or using flammable gases or liquids above the by-law limits |
| Fire equipment compliance | Service providers maintain equipment; inspectors check it | Ongoing, at all premises |
Your landlord, insurer, municipality or customer may ask for a "fire certificate". Ask them which of these they mean.
Building plans and Part T
The National Building Regulations require buildings to be designed for fire safety. SANS 10400-T sets out deemed-to-satisfy rules for fire protection, covering matters such as:
- Escape routes: number of exits, travel distances and exit widths.
- Fire division: separating areas so fire cannot spread quickly.
- Structural fire resistance of walls, floors and roofs.
- Fire detection and alarm where required.
- Fire-fighting equipment: extinguishers, hose reels and hydrants.
- Signage and emergency lighting along escape routes.
A new factory, an extension or a change of use, such as turning a warehouse into a food plant, usually needs plans approved by the municipality, often prepared or checked by a fire engineer where the building does not follow the deemed-to-satisfy rules. The fire department inspects before occupation.
Flammable substance certificates
Many municipal by-laws control how much flammable gas and liquid you may store and use without a certificate. In Cape Town, the owner or person in charge of premises may not store or use more than 100 kg of flammable gas, or more than 200 litres of flammable liquid of danger groups (i) to (iv), without a flammable substance certificate from the controlling authority. Other cities have similar rules; eThekwini's interim code on fire prevention and flammable liquids and substances, for example, covers registration certificates, their display, exemptions and cancellation.
Factory items that often trigger these rules:
| Item | Why it matters |
|---|---|
| Diesel for generators | Backup power tanks can exceed liquid limits |
| LPG for ovens, fryers and boilers | Gas cylinders or bulk tanks exceed gas limits quickly |
| Solvents, thinners and inks | Paint, printing and coating lines |
| Fuel for forklifts | Gas cylinders and diesel |
| Flammable raw materials | Alcohol, oils and some chemicals |
The fire department usually inspects the storage area, tank installation, ventilation, separation distances, signage and fire equipment before issuing the certificate, and may require renewal.
How a production line affects fire approval
A new line can change the building's fire risk. Plan for:
- Heat sources: ovens, fryers, dryers, boilers and burners.
- Fuels: gas supply, diesel tanks, thermal oil systems.
- Dust: flour, sugar, wood and plastics dust can be explosive in the right conditions.
- Combustible stock: plastics, paper, packaging and finished goods.
- Escape routes: machines and conveyors must not block exits.
- Electrical installation: a certificate of compliance for the installation by a registered person.
Share the layout, equipment list and fuel consumption with your fire engineer early, because changes after the line is installed are costly.
Working with your insurer and landlord
Fire approvals are not only a municipal matter. Your insurer will usually ask about the building's construction, fire detection, sprinklers if any, the storage of flammables and combustible stock, and the maintenance of fire equipment, and may set conditions or adjust the premium. If you rent, the lease often makes the tenant responsible for compliance arising from its own use, such as a new gas oven or a diesel tank, while the landlord answers for the building itself.
Before you sign a lease or install a line, ask three questions: does the building's existing approval cover the new use, who pays for any upgrades the fire department requires, and what the insurer needs to see before it covers the new process. Getting these answers in writing early avoids disputes and delays when the inspector arrives.
Steps for a new or changed factory
- Speak to the municipal fire department about your building, process and fuels.
- Appoint a fire engineer or competent person if the design does not follow the deemed-to-satisfy rules.
- Prepare building plans with fire protection to SANS 10400-T and submit them for approval.
- Plan fuel and flammable storage and apply for a flammable substance certificate where limits are exceeded.
- Install fire equipment, detection and signage as approved.
- Arrange the fire department's inspection before occupation or before storing flammables.
- Keep equipment serviced and records available for inspectors and insurers.
Fire safety under the OHS Act
The Occupational Health and Safety Act requires employers to provide a safe workplace, which includes fire prevention, emergency planning and training. In practice that means an emergency plan, trained fire marshals, regular evacuation drills, and maintained fire equipment.
Common mistakes
- Installing a gas oven or diesel generator without checking storage limits.
- Machines blocking escape routes.
- Changing use without new plan approval, such as converting a warehouse to production.
- Expired service tags on extinguishers and hose reels.
- Dust build-up on ledges and in ducts.
- Assuming a landlord's certificate covers your process.
Where CISH fits
CISH supplies, installs and commissions complete production lines from audited factories in China, and provides the layout, equipment list, heat sources, fuel consumption and electrical loads your fire engineer and municipality need. Fire approvals are applied for by the building owner or occupier.
Frequently asked questions
What is a fire compliance certificate in South Africa?
The term is used for several municipal approvals: fire approval of building plans and the completed building under the National Building Regulations, a flammable substance certificate for storing flammables above set limits, and records showing fire equipment is maintained.
Who issues a fire certificate for a factory?
The municipality, through building control and the fire department. Requirements differ between municipalities, so start with your local fire department.
When do I need a flammable substance certificate?
When you store or use flammable gases or liquids above your municipality's limits. In Cape Town, for example, the limits are 100 kg of flammable gas and 200 litres of flammable liquid in the main danger groups.
What is SANS 10400-T?
The part of the national building standard that sets deemed-to-satisfy rules for fire protection, such as escape routes, fire division, fire resistance and fire equipment.
Does installing a new production line affect fire approval?
It can, if it adds heat sources, fuels, dust or combustible stock, or changes escape routes. Check with your fire engineer before installation.
Do I need a fire engineer?
Where the design does not follow the deemed-to-satisfy rules, a rational design by a competent fire engineer is usually needed. Your municipality will advise.
Does a fire certificate need renewing?
Flammable substance certificates and registrations are often renewed periodically, and fire equipment must be serviced on schedule. Ask your municipal fire department about renewal periods for your certificate.
What should I prepare before the fire inspection?
Approved building plans, the layout of escape routes and fire equipment, service records for extinguishers and hose reels, details of flammable storage, your emergency plan and the names of trained fire marshals.