Building rules then set the strength a wall needs: for single-storey houses, hollow units must average at least 3.0 MPa and solid units 4.0–5.0 MPa, rising to 7.0 and 10.0 MPa for double-storey construction. Builders on NHBRC-enrolled homes and formal projects expect blocks that meet these figures, and producers can certify through a SANAS-accredited certification body. CISH supplies complete block plants that make SANS 1215 units consistently.
Regulations change. Confirm the current requirement with the authority named in each section before you commit money.
What SANS 1215 covers
| Requirement | What it means in practice |
|---|---|
| Compressive strength | The main requirement; units are classed by nominal strength |
| Sampling | How many units are taken from a batch for testing |
| Dimensional tolerances | How far each unit may differ from its work size |
| Drying shrinkage and wetting expansion | Limits so walls do not crack as units dry |
| Squareness, texture, appearance | Especially for face units left unplastered |
| Recommended dimensions | In an appendix, based on modular sizes |
The figures on this page are as given in the Concrete Manufacturers Association's Concrete Masonry Manual for SANS 1215:2008. Check the current edition of the standard from the SABS before you design a product or a test regime.
Strength classes
| Nominal compressive strength (MPa) | Minimum average of the sample (MPa) | Minimum for any individual unit (MPa) |
|---|---|---|
| 3.5 | 4.0 | 3.0 |
| 7.0 | 8.0 | 5.5 |
| 10.5 | 11.5 | 8.5 |
| 14.0 | 15.5 | 11.0 |
| 21.0 | 23.5 | 17.0 |
The average is taken over five units, or twelve units for units 290 mm long or shorter. Strength is calculated on the gross area of the unit, so a hollow block's strength is measured on its overall bed face, not only the solid webs.
What strength a wall needs
SANS 1215 says how strong a unit is; building rules say how strong it must be for a given use. The minimums commonly applied for housing, from SANS 2001-CM1 as quoted in the CMA manual, are:
| Use | Hollow units, average / individual (MPa) | Solid units, average / individual (MPa) |
|---|---|---|
| Single-storey, units made on site | 3.0 / 2.4 | 4.0 / 3.2 |
| Single-storey, units made off site | 3.0 / 2.4 | 5.0 / 4.0 |
| Double-storey construction | 7.0 / 5.6 | 10.0 / 8.0 |
| Cladding and internal walls in concrete-framed housing | 3.0 / 2.4 | 5.0 / 4.0 |
"On site" means units carried no more than 25 m from where they are made to the wall. A yard selling to builders is making units off site.
Solid or hollow, brick or block
- Solid units have cavities of no more than 25% of their gross volume.
- Hollow units have cavities of more than 25% and up to 60%.
- A block is a unit between 300 and 650 mm long, or 130 to 300 mm wide and 120 to 300 mm high; anything smaller is a brick.
Modular wall thicknesses under SANS 10400 are 90, 140 and 190 mm, and the standard's appendix recommends modular sizes such as 390 × 140 × 190 mm and 390 × 190 × 190 mm. Many yards also make imperial-based bricks of around 222 × 106 × 73 mm; these must still meet SANS 1215.
Size tolerances
| Dimension | Tolerance |
|---|---|
| Length | +2 mm / −4 mm |
| Width | ±3 mm (±10 mm overall width for face units with an aesthetic finish) |
| Height | ±3 mm |
Tight tolerances matter to builders: units that vary in height make uneven courses and use more mortar.
Shrinkage and water absorption
Drying shrinkage should not exceed 0.06%, and expansion on re-wetting should not exceed the drying shrinkage by more than 0.02%. Units made with slag, clinker or crushed clay brick aggregates should be checked for soundness. SANS 1215 does not specify water absorption for concrete units.
How to meet SANS 1215 in production
| Factor | What the plant must do |
|---|---|
| Mix design | Trial batches with your cement and aggregates, tested to the class you sell |
| Batching | Weigh cement and aggregates; correct for sand moisture |
| Compaction | Enough vibration and pressure to reach density consistently |
| Mould wear | Replace worn moulds before tolerances drift |
| Curing | Keep units moist and protected for the first days |
| Sampling and testing | Test samples from production at an accredited laboratory, and keep records |
| Stock control | Do not sell units before they reach strength |
Certification
Producers can certify their units against SANS 1215 through an accredited certification body, which audits the process and tests samples regularly. CMA Certification Services is a SANAS-accredited certification body for precast concrete products, and its certificates for SANS 1215 are issued for three-year periods. The SABS also runs a certification mark scheme. Certification is not a legal requirement for every sale, but it is the simplest way to show contractors, engineers and housing programmes that your blocks meet the standard.
SANS 1215 and NHBRC homes
New homes enrolled with the National Home Builders Registration Council are built to the National Building Regulations and SANS 10400, which refer to masonry units meeting SANS 1215 and to the minimum strengths above. Home builders and their inspectors therefore ask for blocks of the right class, and many government housing contractors ask for test certificates.
A quick test plan for a block yard
Take samples from each day's production, cure them as your sold product is cured, and have them crushed at an accredited laboratory at the age you sell. Record the batch, mix, date and results, and compare each set against both the average and the individual minimums for the class you claim.
Common mistakes
- Testing one block instead of a proper sample.
- Selling the class you hope for, not the class you tested.
- Ignoring individual minimums: one weak unit fails the batch.
- Worn moulds pushing sizes out of tolerance.
- No curing, so units miss their strength.
- Mixing up SANS 1215 and SANS 1058: pavers have their own standard.
Where CISH fits
CISH supplies complete block and brick plants from audited factories in China, with weigh-batching, moisture correction, compaction and curing designed to make SANS 1215 units of the class you sell, consistently. We ship and clear the plant, install and commission it with output and unit quality demonstrated on your aggregates, and train your team. Testing and certification are arranged by the producer with an accredited laboratory and certification body.
Frequently asked questions
What is SANS 1215?
The South African standard for concrete masonry units, the cement bricks and blocks used in walls, covering strength, sampling, tolerances and shrinkage.
What strength must cement blocks have in South Africa?
It depends on the use. For single-storey houses, hollow units commonly need an average of at least 3.0 MPa and solid units 4.0–5.0 MPa; double-storey construction needs 7.0 MPa hollow and 10.0 MPa solid.
What are the SANS 1215 strength classes?
Nominal compressive strengths of 3.5, 7.0, 10.5, 14.0 and 21.0 MPa, each with a minimum sample average and a minimum for individual units.
How many blocks are tested for SANS 1215?
The average is based on five units, or twelve units for units 290 mm long or shorter.
What is the size tolerance for concrete blocks?
Length +2 mm or −4 mm, width ±3 mm and height ±3 mm, with a wider width tolerance for some face units.
Is SANS 1215 certification compulsory?
Not for every sale, but builders, engineers and housing projects often require tested or certified units. Certification is through an accredited certification body.
Does CISH test blocks?
No. We supply the plant; testing and certification are done by accredited laboratories and certification bodies.